Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
184 Configuration Manual, 11/2014, C79000-G8976-C351-03
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan overlap-ap aging <min(1-7200)>
The parameter has the following meaning:
Parameters
Description
Values or range of values
min
Time in minutes (min) 1...7200
Default: 120
Result
The aging time is specified.
Further notes
You display the setting with the show wlan advanced <wlan 0/X> command.
6.1.5.48
wlan roaming threshold (client)
Description
With this command, you specify the threshold after which the client roams to the new access
point.
Note
This command is only available in the client
mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals