EasyManuals Logo

Siemens SCALANCE W760 Configuration Manual

Siemens SCALANCE W760
432 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #166 background imageLoading...
Page #166 background image
Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
166 Configuration Manual, 11/2014, C79000-G8976-C351-03
Result
The MCS indexes are assigned to the WLAN interface.
Further notes
You display the setting with the show wlan data rates command.
You enable the function with the
wlan data rates-11n selected only command.
You configure the transmission standard with the
wlan mode command.
6.1.5.28
wlan data rate-11abg defaults (access point)
Description
You can reset the selection to the default setting with this command.
Note
This command is availab
le only in access point mode.
Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
The transmission standard IEEE 802.11a/b/g/n is set.
The "Use selected data rates only" function is enabled.
Syntax
Call the command without parameter assignment:
wlan data rate-11abg defaults
Result
The selection is reset to the default setting.

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals