Diagnostics
11.1 Diagnostics
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
420 Configuration Manual, 11/2014, C79000-G8976-C351-03
Syntax
Call up the command with the following parameters:
no severity { mail | log | syslog }
The parameters have the following meaning:
Parameter
Description
Range of values / note
mail
The setting of the threshold value for
sending system event messages by e-
mail is disabled.
-
log
The setting of the threshold value for
entering system event messages in the
log table disabled.
-
syslog
The setting of the threshold value the
entering event messages in the Syslog
file is disabled.
-
If you do not select any parameters from the parameter list, the default value is used.
Result
The settings for sending system event messages are configured.
Further notes
You enable the setting with the severity command.
You display the status of this function and other information
show events severity.
11.1.14.8
link
Description
With this command, you configure and enable the monitoring of the physical network
connections for cable breaks or for pulling of the connector.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals