Network protocols
7.6 HTTP server
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
338 Configuration Manual, 11/2014, C79000-G8976-C351-03
7.6.2.1
ip http
Description
With this command, you enable HTTP on the device.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
ip http
As default the function is "enabled".
Result
HTTP is enabled on the device.
Further notes
You can display the setting of this function and other information with the show ip http
server status
command.
You deactivate HTTP on the device with the
no ip http command.
7.6.2.2
no ip http
Description
With this command, you disable HTTP on the device.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#