Configuration
3.4 Configuration Save & Restore
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
77
Parameter
Description
Range of values
auto-logout
Shows the configuration settings of the auto
logout function
-
time
Shows the configuration settings of the system
time
-
ntp
Shows the configuration settings of the Network
Time Protocol
-
auto-save
Shows the configuration settings of the auto
save function
-
wlan
Shows the configuration settings of the WLAN
-
all
Shows all configuration settings
-
For information on identifiers of interfaces and addresses, refer to the section "Interface
identifiers and addresses (Page 23)".
If you call up the command without parameters, only the active operational settings of all
modules and all interfaces that do not match the preset values are displayed.
Result
The selected configuration settings of the device are displayed.
3.4.2
write startup-config
Description
With this command, you save the changes to the configuration in the configuration file.
The use of this command is required in the Trial mode. It can also be used in "auto save
mode".
Requirement
The Trial mode is activated.
You are in the Privileged EXEC mode.
The command prompt is:
*cli(...)#
Syntax
Call the command without parameter assignment:
write startup-config

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals