Network protocols
7.4 SNMP
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
325
Syntax
Call the command without parameters:
snmp v1-v2 readonly
Result
Write access for SNMPv1 and SNMPv2 PDUs is blocked.
Further notes
You release write access for SNMPv1 and SNMPv2 PDUs with the no snmp v1-v2 readonly
command.
7.4.2.19
no snmp v1-v2 readonly
Description
With this command, you enable write access for SNMPv1 and SNMPv2 PDUs.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no snmp v1-v2 readonly
Result
Write access for SNMPv1 and SNMPv2 PDUs is enabled.
Further notes
You block write access for SNMPv1 and SNMPv2 PDUs with the snmp v1-v2 readonly
command.