Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
186 Configuration Manual, 11/2014, C79000-G8976-C351-03
Result
The packet size is specified.
Further notes
You display the setting with the show wlan advanced <wlan 0/X> command.
6.1.6
Commands in the VAP Interface Configuration mode
This section describes commands that you can call up in the VAP Interface Configuration
mode. Depending on the Interface selected, various command sets are available.
In the Global Configuration mode, enter the
interface vapX 0/Y command to change to this
mode.
If you exit the VAP Interface Configuration mode with the
exit command, you return to
the Global Configuration mode.
If you exit the VAP Interface Configuration mode with the
end command, you return to the
Privileged EXEC mode.
6.1.6.1
vap wds id (access point)
Description
With this command, you set the WDS ID for the relevant VAP interface. To establish a WDS
connection, enter this WDS ID on the WDS partner.
Note
This command is available only in access point mode
.
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals