Security and authentication
10.2 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
398 Configuration Manual, 11/2014, C79000-G8976-C351-03
10.2.6.11
no vap communication with ethernet (access point)
Description
With this command, you specify that the client cannot communicate via the Ethernet
interface.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
Syntax
Call the command without parameter assignment:
no vap communication with ethernet
Result
The communication option is disabled.
Further notes
You display the settings with the show wlan security <vapX 0/Y> command.
You enable the function with the
vap communication with ethernet command.