EasyManua.ls Logo

Siemens SCALANCE W760 - Snmp Notify

Siemens SCALANCE W760
432 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Network protocols
7.4 SNMP
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
318 Configuration Manual, 11/2014, C79000-G8976-C351-03
7.4.2.12
snmp notify
Description
With this command, you configure the details of the SNMP notifications.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp notify <NotifyName> tag <TagName> type {Trap|Inform}
[{volatile|nonvolatile}]]
The parameters have the following meaning:
Parameter
Description
Range of values / note
NotifyName
Name of the SNMP notification
max. 32 characters
tag
Keyword for a target key -
TagName
Name of the target key
max. 32 characters
Type
Type of the SNMP notification
Trap
generates a trap
Inform
generates a log entry or sends
an entry to the log server
Storage type specifies whether the settings remain
following a restart:
volatile (volatile):
The settings are lost after a
restart
nonvolatile (non-volatile):
The settings are retained after
a restart
Result
The details of the SNMP notifications are configured.