Network protocols
7.4 SNMP
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
322 Configuration Manual, 11/2014, C79000-G8976-C351-03
Syntax
Call up the command with the following parameters:
no snmp targetaddr <TargetAddressName>
The parameters have the following meaning:
Parameter
Description
Range of values / note
TargetAddressName
SNMP target address
max. 32 characters
Result
The SNMP target address is deleted.
Further notes
You change the SNMP target address with the snmp targetaddr command.
You display the SNMP target address with the
show snmp targetaddr command.
7.4.2.16
snmp targetparams
Description
With this command, you configure the SNMP target parameters.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp targetparams <ParamName>
user <UserName>
security-model {v1|v2c|v3{auth|noauth|priv}}
message-processing {v1|v2c|v3}[{volatile|nonvolatile}]
The parameters have the following meaning:
Parameter
Description
Range of values / note
ParamName
Name of the SNMP parameter
max. 32 characters
user
Keyword for the user name
-
UserName
Value for the user name max. 32 characters

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals