Network protocols
7.4 SNMP
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
324 Configuration Manual, 11/2014, C79000-G8976-C351-03
7.4.2.17
no snmp targetparams
Description
With this command, you delete the SNMP target parameters.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no snmp targetparams <ParamName>
The parameter has the following meaning:
Parameter
Description
Range of values / note
ParamName
Name of the SNMP parameter
max. 32 characters
Result
The SNMP target parameters are deleted.
Further notes
You change the SNMP target parameters with the snmp targetparams command.
You display settings of this function with the
show targetparam command.
7.4.2.18
snmp v1-v2 readonly
Description
With this command, you block write access for SNMPv1 and SNMPv2 PDUs.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals