EasyManuals Logo

Siemens SCALANCE W760 Configuration Manual

Siemens SCALANCE W760
432 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #113 background imageLoading...
Page #113 background image
System time
5.3 SNTP client
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
113
Further notes
You can display the settings of this function and other information with the show sntp
status
command.
5.3.5.2
sntp unicast-server
Description
With this command, you configure an SNTP unicast server.
Requirement
The addressing mode of the SNTP client is configured as "unicast".
You are in the SNTP Configuration mode.
The command prompt is:
cli(config-sntp)#
Syntax
Call up the command with the following parameters:
sntp unicast-server {ipv4 <ucast_addr> | fqdn-name <FQDN(100)>} [port<1025-
36564>][poll<seconds(16-16284)>]
The parameters have the following meaning:
Parameter
Description
Range of values / note
ipv4
Keyword for an IP address
-
ucast_addr
Value for an IPv4 unicast address Enter a valid IPv4 unicast ad-
dress.
fqdn-name
Keyword for a domain name
-
FQDN(100)
Domain name (Fully Qualified Domain
Name)
Maximum of 100 characters
port
UDP port of the time server 1025 … 36564
Default: 123
poll
Keyword for the time after which the
time of day is requested again
-
seconds
Value for the time in seconds
16 ... 16284
Result
The SNTP unicast server is configured.

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals