Network protocols
7.4 SNMP
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
327
Further notes
You delete the settings with the no snmp user command.
You display the configured users with the
show snmp user command.
7.4.2.21
no snmp user
Description
With this command, you delete the details of an SNMP user.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no snmp user <UserName>
The parameter has the following meaning:
Parameter
Description
Range of values / note
UserName
Name of the user
max. 32 characters
Result
The details of the SNMP user are deleted.
Further notes
You change the settings with the snmp user command.
You display the configured users with the
show snmp user command.