Network protocols
7.2 DHCP client
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
278 Configuration Manual, 11/2014, C79000-G8976-C351-03
Result
The configuration settings of the DHCP client are displayed.
7.2.3
renew dhcp
Description
This command reassigns an IP address to the selected interface via DHCP.
Requirement
The IP address of the selected interface was assigned via DHCP.
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#
Syntax
Call up the command with the following parameters:
renew dhcp [{vlan<vlan-id(1-4094)>|<interface-type><interface-id>}]
The parameters have the following meaning:
Parameter
Description
Range of values
vlan
Keyword for a VLAN connection
-
vlan-id
Number of the addressed VLAN
1 ... 4094
interface-
type
Type or speed of the interface Enter a valid interface.
interface-id
Module no. and port no. of the interface
For information on identifiers of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 23)".
Result
The IP address is assigned again.
This address can be a different address from the previously assigned address.
Further notes
You can display the statistical information of the DHCP client with the show ip dhcp client
stats
command.
You show the statistical information and the configuration of the IP interface with the
show ip
interface
command.

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
Product TypeWireless Access Point
Frequency Bands2.4 GHz, 5 GHz
Wireless StandardsIEEE 802.11a/b/g/n/ac
Number of Antennas2
Power Supply24 V DC
Operating Temperature-20°C to +60°C
Operating Voltage24 V DC
Protection ClassIP65
Antenna ConnectorsR-SMA
SecurityWPA2, WPA3

Related product manuals