Network structures
6.1 WLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
164 Configuration Manual, 11/2014, C79000-G8976-C351-03
Syntax
Call up the command with the following parameters:
wlan data rate-11abg {show-rates | {{add | del} <rate> | all | none} [basic]}
The parameters have the following meaning:
Parameters
Description
show-rates
Shows a list of the available data transmission speeds.
add
The data transmission speed is assigned to the WLAN interface entered
in the <
rate
> parameter.
del
The data transmission speed is removed from the WLAN interface en-
tered in the <rate> parameter.
rate
Data transmission speed
all
All available data transmission speeds are assigned to the WLAN inter-
face.
none
Only the first available data transmission speed is assigned to the
WLAN interface. The other data transmission rates are deselected.
basic
The data transmission speed entered in the <rate> parameter is de-
clared as "Basic".
The "basic" parameter can only be called in conjunction with the pa-
rameters "add", "del", "all" and "none".
Note
You need to assign at least one data transmission speed and one "
Basic" to the WLAN
interface.
Result
The data transmission speeds are assigned to the WLAN interface.
Further notes
You display the setting with the show wlan data rates command.
You enable the function with the
wlan data rates-11abg selected only command.
You configure the transmission standard with the
wlan mode command.
You can reset the selection to the default setting with the
wlan data rate-11abg defaults
command.

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals