Network protocols
7.4 SNMP
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
310 Configuration Manual, 11/2014, C79000-G8976-C351-03
Parameter
Description
Range of values / note
- Selects the authentication method:
•
auth
enables MD5 or SHA as au-
thentication method
• noauth
no authentication
•
priv
enables authentication and
encryption
read
the data can be read
Keyword
•
ReadView
•
none
write
the data can be read and written
Keyword
•
WriteView
•
none
notify
Changes can be set as a tag
Keyword
•
NotifyView
•
none
Storage type specifies whether the settings remain
following a restart
•
volatile (volatile):
The settings are lost after a
restart
•
nonvolatile (non-volatile):
The settings are retained after
a restart
The keywords need to be specified.
If optional parameters are not specified when configuring a group, the default value will be
used.
Result
The settings for access to an SNMP group are configured.
Further notes
You delete the access to an SNMP group with the no snmp access command.
You display the configured SNMP groups with the
show snmp group command.
You display the access configurations for SNMP groups with the
show snmp group access
command.
You display the configured SNMP tree views with the
show snmp viewtree command.

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W760
CategoryWireless Access Point
LanguageEnglish

Related product manuals