Network protocols
7.4 SNMP
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
310 Configuration Manual, 11/2014, C79000-G8976-C351-03
Parameter
Description
Range of values / note
- Selects the authentication method:
auth
enables MD5 or SHA as au-
thentication method
noauth
no authentication
priv
enables authentication and
encryption
read
the data can be read
Keyword
ReadView
none
write
the data can be read and written
Keyword
WriteView
none
notify
Changes can be set as a tag
Keyword
NotifyView
none
Storage type specifies whether the settings remain
following a restart
volatile (volatile):
The settings are lost after a
restart
nonvolatile (non-volatile):
The settings are retained after
a restart
The keywords need to be specified.
If optional parameters are not specified when configuring a group, the default value will be
used.
Result
The settings for access to an SNMP group are configured.
Further notes
You delete the access to an SNMP group with the no snmp access command.
You display the configured SNMP groups with the
show snmp group command.
You display the access configurations for SNMP groups with the
show snmp group access
command.
You display the configured SNMP tree views with the
show snmp viewtree command.

Table of Contents