Load control
8.1 Dynamic MAC aging
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
347
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
mac-address-table aging-time <seconds(10-1000000)>
The parameter has the following meaning:
Parameters
Description
Range of values
seconds
Life of the entry in seconds
10 ... 1000000
At system start or when using the restart command with the option memoryor factory, the
following defaults apply:
The function is configured to 300 seconds.
Result
The value of the aging of a dynamically learned entry is configured.
Further notes
You can reset the setting to the default with the no mac-address-table aging-time command.
You display the setting with the
show mac-address-table aging-time command.

Table of Contents

Other manuals for Siemens SCALANCE W760

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W760 and is the answer not in the manual?

Siemens SCALANCE W760 Specifications

General IconGeneral
Product TypeWireless Access Point
Frequency Bands2.4 GHz, 5 GHz
Wireless StandardsIEEE 802.11a/b/g/n/ac
Number of Antennas2
Power Supply24 V DC
Operating Temperature-20°C to +60°C
Operating Voltage24 V DC
Protection ClassIP65
Antenna ConnectorsR-SMA
SecurityWPA2, WPA3

Related product manuals