Layer 3 functions
9.1 NAT
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
357
Requirement
You are now in the NAT Configuration mode.
The command prompt is as follows:
cli(config-nat)#
Syntax
Call up the command with the following parameters:
nat {tcp|udp} timeout <seconds>
The parameters have the following meaning:
Parameters
Description
Values
tcp
TCP connection
-
udp
UDP connection
-
seconds
Period of time in seconds
1 ... 4294967295
Result
The period of time is configured.
Further notes
You show the NAT configuration and the translation list with the show nat command.
You delete the period of time with the
no nat timeout command.
See also
show nat (client) (Page 349)