Command groups
Table 2-40: Trigger commands (cont.)
Command
Description
TRIGger:{A|B}:BUS:B<x>:ETHERnet:DATa:
SIZe
When the Ethernet trigger condition is set to DATa, this command specifies the
number of contiguous TCP/IPv4/MAC client data bytes to trigger on.
TRIGger:{A|B}:BUS:B<x>:ETHERnet:DATa:
VALue
When the Ethernet trigger condition is set to DATa, and the qualifier is set
to
LESSthan, MOREthan, EQual, UNEQual, LESSEQual or
MOREEQual, this command specifies the value to trigger on.
TRIGger:{A|B}:BUS:B<x>:ETHERnet:
IPHeader:DESTinationaddr:VALue
When the Ethernet trigger condition is set to IPHeader, this command specifies
the value of the 32–bit destination address that is to be used in the trigger.
TRIGger:{A|B}:BUS:B<x>:ETHERnet:
IPHeader:PROTOcol:VALue
When the Ethernet trigger condition is set to IPHeader, this command specifies
the value of the 8–bit protocol field that is to be used in the trigger.
TRIGger:{A|B}:BUS:B<x>:ETHERnet:
IPHeader:SOUrceaddr:VALue
When the Ethernet trigger condition is set to IPHeader, this command specifies
the value of the 32-bit s ource address that is to be used in the trigger.
TRIGger:{A|B}:BUS:B<x>:ETHERnet:MAC:
ADDRess:DESTination:VALue
When the Ethernet trigger condition is set to MACADDress, this command specifies
the 48–bit MAC destination address that is to be used in the trigger.
TRIGger:{A|B}:BUS:B<x>:ETHERnet:MAC:
ADDRess:SOUrce:VALue
When the Ethernet trigger condition is set to MACADDress, this command specifies
the 48–bit MAC source address value that is to be used in the trigger.
TRIGger:{A|B}:BUS:B<x>:ETHERnet:MAC:
LENgth:HIVALue
When the Ethernet trigger condition is set to MACLENgth, and the qualifier is set to
INrange or OUTrange, this command specifies the upper data value of the range.
TRIGger:{A|B}:BUS:B<x>:ETHERnet:MAC:
LENgth:VALue
When the Ethernet trigger condition is set to MACLENgth, and the qualifier
is set to
LESSthan, MOREthan, EQual, UNEQual, LESSEQual or
MOREEQual, this command specifies the 16–bit value to trigger on.
TRIGger:{A|B}:BUS:B<x>:ETHERnet:QTAG:
VALue
When the Ethernet trigger condition is set to QTAG, this command specifies the
32-bit Q-Tag value to trigger on.
TRIGger:{A|B}:BUS:B<x>:ETHERnet:
TCPHeader:ACKnum:VALue
When the Ethernet trigger condition is set to TCPHeader, this command specifies
the 32–bit acknowledgement number that is to be used in the trigger.
TRIGger:{A|B}:BUS:B<x>:ETHERnet:
TCPHeader:DESTinationport:VALue
When the Ethernet trigger condition is set TCPHeader, this command specifies the
16–bit destination port address value that is to be used in the trigger.
TRIGger:{A|B}:BUS:B<x>:ETHERnet:
TCPHeader:SEQnum:VALue
When the Ethernet trigger condition is set to TCPHeader, this command specifies
the 32–bit sequence number that is to be used in the trigger.
TRIGger:{A|B}:BUS:B<x>:ETHERnet:
TCPHeader:SOUrceport:VALue
When the Ethernet trigger condition is set to TCPHeader, this command specifies
the 16–bit source port address that is to be used in the trigger.
TRIGger:{A|B}:BUS:B<x>:FLEXray:
CONDition
Specifies the condition to use when triggering on a FlexRay bus signal (start of
frame, frame type, ID, cycle count, header, data, ID and data, EOF, error).
TRIGger:{A|B}:BUS:B<x>:FLEXray:
CYCLEcount:HIVALue
Specifies the high value when triggering on a FlexRay bus cycle count field.
TRIGger:{A|B}:BUS:B<x>:FLEXray:
CYCLEcount:QUALifier
Specifies the qualifier (<, >, =, <=, >=, ≠, in range, out of range) to use when
triggering on the FlexRay bus cycle count field.
TRIGger:{A|B}:BUS:B<x>:FLEXray:
CYCLEcount:VALue
Specifies the low value when triggering on the FlexRay bus cycle count field.
TRIGger:{A|B}:BUS:B<x>:FLEXray:DATa:
HIVALue
Specifies the high value when triggering on the FlexRay bus data field.
TRIGger:{A|B}:BUS:B<x>:FLEXray:DATa:
OFFSet
Specifies the offset of the data string, in bytes, when triggering on the FlexRay
bus data field.
2-78 MSO54, MSO56, MSO58, MSO58LP Programmer