EasyManua.ls Logo

Cypress FM4 Series - Page 142

Cypress FM4 Series
1102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 3: Clock Supervisor
142 FM4 Peripheral Manual, Doc. No. 002-04856 Rev. *E
Anomalous Frequency Detection
Figure 2-2 shows the block diagram of the anomalous frequency detection.
Figure 2-2 Anomalous Frequency Detection Block Diagram
The anomalous frequency detection consists of the following three types of blocks.
Control circuit/register and window registers
This block includes a circuit controlling the anomalous frequency detection.
Also includes setup registers enabling/disabling the anomalous frequency detection.
Also includes window registers defining the frequency range for measurements.
Frequency counter
A counter based on the main clock.
Divider/edge detection
This block divides the high-speed CR.
Also detects rising edges of the divided clock of high-speed CR.
Frequency
counter
Control circuit /
register and
window registers
Edge
detection
divider
FCS_RESET
Main Clock
High-speed CR
FCS_INT