CHAPTER 11: DSTC
516 FM4 Peripheral Manual, Doc. No. 002-04856 Rev. *E
The values of DES3 (transfer destination address) after the end of the transfer are updated according to
the values of MODE, DAC[2:0] and ORL[2] of DES0 at the start of the transfer as shown in Table 3-7. "X"
in Table 3-7 indicates that value has no effect on operation. If the start value of DES3 is different from the
end value, rebuild DES3 before restart to transfer.
Table 3-7 Values of DES2 after Transfer End
Values of DES0 at Transfer Start
Values of DES3 after Transfer End
Necessity of
Rebuilding DES3
Transfer destination address at final outer loop start
Transfer destination address of final transfer
Values of DES6 are copied.
The setting is that DES0.DV[1]=1 and DES1,2,3 is need to rebuild (DES1,2,3 is not returned to the start
value), caused to notify a DES open error from the DSTC. For details, see 3.2.8 MONERS Register.