CHAPTER 19: Programmable CRC
948 FM4 Peripheral Manual, Doc. No. 002-04856 Rev. *E
Access
Application
Write 0
Prohibits the transfer request of input data for DMA.
In case that a transfer has been already requested, the transfer request will be canceled.
Write 1
Allows the transfer request of input data for DMA.
Read
Reads the register setting value.
Write access to this register is not allowed when CRC computing is performed
(PRGCRC_CFG.LOCK="1").
[bit27] Reserved bits
Writing has no effect in operation. Read value is always "0".
[bit28] LOCK(PRGCRC lock)
Access
Application
Write
No effect in operation.
Read 0
Indicates the CRC computing unit is in idle state.
Indicates writing to all registers is possible.
Indicates that the started CRC computing has been completed.
Read 1
Indicates the CRC computing unit is in busy state.
Indicates writing to all registers is ignored.
Indicates that the started CRC computing has not been completed.
[bit31:29] Reserved bits
Writing has no effect in operation. Read value is always "0".