Model 4200A
-SCS Parameter Analyzer Reference Manual Section 13:
LPT library function reference
4200A-901-01 Rev. C / February 2017 13-3
Command Description
kibdefdelete (on page
13-23)
Deletes all command definitions previously made with the
kibdefclr
(Keithley
GPIB define device clear) and kibdefint (Keithley GPIB define device initialize)
commands.
kibdefint (on page 13-24)
Defines a device-dependent command sent to an instrument connected to the GPIB
interface.
kibrcv (on page 13-25)
Reads a device-dependent string from an instrument connected to the GPIB
interface.
kibsnd (on page 13-26)
Sends a device-dependent command to an instrument connected to the GPIB
interface.
kibspl (on page 13-27)
Serial polls an instrument connected to the GPIB interface.
kibsplw (on page 13-28)
Synchronously serial polls an instrument connected to the GPIB interface.
kspcfg (on page 13-28)
Configures and allocates a serial port for RS-232 communications.
kspdefclr (on page 13-
29)
Defines a device-dependent character string sent to an instrument connected to a
serial port.
kspdefdelete (on page
13-30)
Deletes all command definitions previously made with the kspdefclr (Keithley
Serial Define Device Clear) and kspdefint (Keithley Serial Define Device
Initialize) commands.
kspdefint (on page 13-
31)
Defines a device-dependent character string sent to an instrument connected to a
serial port.
ksprcv (on page 13-32)
Reads data from an instrument connected to a serial port.
kspsnd (on page 13-32)
Sends a device-dependent command to an instrument attached to a RS-232 serial
port.
PostDataDouble (on
page 13-33)
Posts double-precision floating point data from memory into the Clarius Analyze
sheet.
PostDataInt (on page 13-
34)
Posts an integer-type data point from memory to the Clarius Analyze sheet in the
user test module and plots it on the graph.
PostDataString (on page
13-35)
Transfers a string from memory into the Clarius Analyze sheet in the user test
module and plots it on the graph.
rdelay (on page 13-35)
Sets a user-programmable delay.
rtfary (on page 13-36)
Returns the force array determined by the instrument action.
savgX (on page 13-36)
Makes an averaging measurement for every point in a sweep.
scnmeas (on page 13-
38)
Makes a single measurement on multiple instruments at the same time.
searchX (on page 13-38) Used to determine the voltage or current required to get a current or voltage.
setmode (on page 13-42)
Sets instrument-specific operating mode parameters.
sintgX (on page 13-44)
Makes an integrated measurement for every point in a sweep.
smeasX (on page 13-45)
Allows a number of measurements to be made by a specified instrument during a
sweepX command. The results of the measurements are stored in the defined
array.
trigcomp (on page 13-47) Causes a trigger when an instrument goes in or out of compliance.
trigXg, trigXl (on page
13-47)
Monitors for a predetermined level of voltage, current, or time.
tstdsl (on page 13-50)
Deselects a test station.
tstsel (on page 13-50)
Enables or disables a test station.