Materials required
Two plugs measuring 8 mm
.
Depending on the composition of the wall, additional fixing accessories may be required
(for example wood screws for wooden walls).
Procedure
Step Action
1. Loosen and remove sunshade.
2. Loosen triangular head screws, which hold outdoor casing on mounting plate, and remove
outdoor casing. The two triangular head screws are used for mounting the outdoor casing on
the wall. Open casing (four triangular head screws in cover).
3.
Drill two plug holes (8 mm ) in the mounting wall (spacing measurements in Figure 12-3).
Insert plugs.
4. Screw both triangular head screws into plugs until there is a space of about 12 mm between
the head of the screw and the wall.
5. Hang bottom plate of outdoor casing, with its joiners (upper left and lower right), onto the
screws. Tighten triangular head screws.
6. Connect the BS (see Section 12.3.3).
7. Using adhesive tape, fix BS onto heating board plate (Figure 12-6). Then place BS and heating
board plate into the cavity provided in the outdoor casing. Ensure that it fits securely.
The heating board for regulating the temperature in the outdoor casing has not yet been
released for operation with Hicom cordless 150 E Version 1.0!
DO NOT connect the heating board! This could cause the system to malfunction due to
self-heating.
Step Action
8. Close outdoor casing cover using the four triangular head screws.
12.3.3 Connecting the base station
Procedure for connecting BS (indoors and outdoors)
Step Action
1. Locate free interface on the MDFU/MDFU-E for connecting the BS
(configuration of stripping/jumpering strips)