Siemens Hicom 150 E Office - Table 3-20 STMD8 - LED States (H301 to H308)

Siemens Hicom 150 E Office
672 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 3-26 S
0
bus - example of wall socket assignment
An ISDN terminal can also be connected to an existing terminal of the optiset E
series (with the exception of optiset E entry, optiset E standard) by means of an ISDN
adapter (configurations shown in Table 9-7).
LED states and their meaning
LED H300 (see Figure 3-20): reference clock display (clock is generated if this feature has been
configured by means of Hicom Assistant E.)
- On: Reference clock for clock generator is generated.
- Off: No reference clock
LEDs H301 to H308 (see Figure 3-20)
Table 3-20 STMD8 - LED states (H301 to H308)
LED state
(on/off)
Meaning Action
During the boot phase/initialisation
Flickering
(50/50 ms)
Board test not successful Replace board
Hicom 150 E Office Rel.1.0 Service Manual - 3.3 Peripheral boards
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_32.htm (16 of 46) [06/04/2000 13:03:53]