7.6 Features for outgoing external traffic
7.6.1 Last Number Redial (LNR)
Definition
Each time an outgoing call is set up, the extension number dialled is stored. If the call is not put
through, you can press the redial key to redial the same number and set up another call.
The system automatically redials the extension number that was last dialled from the subscriber
extension. This feature is usually implemented when a dialled number is busy or the extension does
not answer.
Any speed-dialling numbers used overwrite the redial memory.
Model-Specific Data
Subject OfficePro OfficeCom OfficePoint OfficeOne
Feature available in x x x x
HW requirements - - - -
SW requirements As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0
Max. length of stored number 25
digits+code
25
digits+code
25
digits+code
25
digits+code
Dependencies/Limitations
Subject Dependency/Limitation
LNR DTMF signals are not regarded as dialling information and are therefore not stored.
Code lock You cannot use the redial feature if the code lock has been activated.
Internal calls Setting up internal calls has no effect on the redial
memory.
Configuration options
This feature does not have to be explicitly configured.
Performing Feature Check
Check the feature for error-free functioning as follows:
Step Action
1. Set up an external connection.
2. Release the external connection.
Hicom 150 E Office Rel.1.0 Service Manual - 7.6 Features for outgoing external traffic
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_76.htm (1 of 21) [06/04/2000 13:10:45]