OfficeCom/OfficePoint.
Figure 3-34 TLA8 interfaces (S30817-Q926-Axxx)
Table 3-26 TLA8 contact assignment
Contact Conn. X3 Conn. X2 Conn. X4 Conn. X5
1 GND a trunk1 a trunk5 GND
2 b trunk 1 b trunk 1 b trunk 5 b trunk 5
3 a trunk 1 a trunk 2 a trunk 6 a trunk 5
4 b trunk 2 b trunk 2 b trunk 6 b trunk 6
5 a trunk 2 a trunk 3 a trunk 7 a trunk 6
6 b trunk 3 b trunk 3 b trunk 7 b trunk 7
7 a trunk 3 a trunk 4 a trunk 8 a trunk 7
8 b trunk 4 b trunk 4 b trunk 8 b trunk 8
9 a trunk 4 a trunk 8
10 GMZ 1 GMZ 2
GMZ= Call charging module assignment
GND=GND for GEE50 FKR, otherwise free
3.3.10 TML8W
Introduction
A TML8W (trunk module loop start world) board can be used to provide 8 analog trunks for Hicom
150 E OfficePro using the loop start method.
The jumpers on the TML8W must be set in accordance with the relevant call detail recording process
with a GEE8 plug module.
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_32.htm (28 of 46) [06/04/2000 13:03:54]