8.25 Remote administration via ISDN
Introduction
Remote administration via ISDN allows you to read out the CDB contents, modify them if applicable,
and transfer them back to the system.
Three variants of remote administration via ISDN are available:
1. Enable procedure (default)
2. Logon without code
3. Logon with code
Example
Release (default): remote administration with an enable procedure is entered in the system as the
default setting. Customers must simply change the code to enable it (default = 000 000).
Step Entry Action Display
1.
*95
From system administration, start "User data" User data
2. 20 Activate Code, RMA Old code:
3. ******
(old code,
000 000)
Enter old code (default 000 000) New code:
4. *** ***
(new code)
Enter new code Repeat:
5. *** ***
(repeat new code)
Confirm new code New code saved
6. F8 F7 Exit User data menu
Example
Logon without code: data can be loaded to and from the system at any time without code entry.
Programming with Hicom Assistant T
Step Entry Action Display
1. *95 31994 Start system administration System Administration
2. 30-2 Activate Remote Admin menu, ISDN Access, CO Access: Release
3.
* 1
Enter "Without code" Access: Without code
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_825.htm (1 of 3) [06/04/2000 13:13:37]