4. F8-F7 Exit system administration Set time, Set date
Programming with Hicom Assistant E
Step Action
1. File -> Transfer -> Callback connection
Code for remote administration cannot be set with the tool!
Example
Logon with code: data can be loaded from the system at any time by entering a 6-digit code
(modifiable by customer) in the tool.
Programming with Hicom Assistant T.
Step Entry Action Display
1. *95 31994 Start system administration System Administration
2. 30-2 Activate Remote Admin menu, ISDN Access, CO Access: Release
3.
* 2
Enter "With code" Access: With code
4. F8-F7 Exit system administration Set time, Set date
Programming with Hicom Assistant E
Step Action
1. File -> Transfer -> Callback connection
Code for remote administration cannot be set with the tool!
Example
The code is to be changed
Step Entry Action Display
1. *95 Start "User data" from system administration. User data
2. 20 Activate Remote Admin menu Old code:
3. ******
(old code,
000 000)
Enter old code (default = 000 000) New code:
4. *** ***
(new code)
Enter new code Repeat:
5. *** ***
(repeat new code)
Confirm new code New code saved