Step Action
1. Configure silent reversal for each trunk line
Options
2. Lines / networking
3. Param
4. MSI flags
5. Check Silent-Reversal
Performing Feature Check
Check the feature for error-free functioning as follows:
Step Action
1. Cannot be tested in Germany
7.12.2 Advice of Charges During Call (AOC-D)
Definition
The recording of call charge criteria basically applies for analog and digital lines.
Call charge evaluation for connections via loop start trunk lines is performed using the call charge
pulses transmitted from the trunk.
In the case of digital lines, the display on the user`s terminal shows the call charge information
received during an external call with the "AOC" (advice of charge) feature, assuming that the carrier
provides the information.
The following types of AOC are supported in the public network:
AOC-D = Advice of charges during call
AOC-E = Advice of charges at end of call
Provided that the user has not initiated another action, at the end of a call the final call charges for a
call are displayed for a specific period of time and then added up in the call charge memory.
Model-Specific Data
Subject OfficePro OfficeCom OfficePoint OfficeOne
Feature available
in
x x x x
HW requirements With loop start:
GEE8;
optiset E
terminal with
display
With loop start:
GEE12/16/50;
optiset E
terminal with display
With loop start:
GEE12/16/50;
optiset E
terminal with display
optiset E
terminal with
display
Hicom 150 E Office Rel.1.0 Service Manual - 7.12 Features for Call Detail Recording
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_712.htm (2 of 21) [06/04/2000 13:08:17]