SW requirements As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0
General
requirements
Call information from public network
Dependencies/Limitations
Subject Dependency/Limitation
a/b terminals On a/b terminals, call charges can be updated by means of a relay and in conjunction
with a call charge counter.
Loop start With loop start trunks, a separate call metering receiving equipment board is required.
Transfer In the case of AOC-D, the extension to which a call is transferred receives only those
call charges that were accrued since the time of the transfer.
Recall If a call is returned as a recall for "unscreened transfer", the overall amount is
displayed and calculated.
Shuttle In the case of the shuttle feature, the call charges for the current call are always
displayed.
Configuration options
The feature can be configured using:
Hicom Assistant T / Hicom Assistant E
Programming Feature Via Hicom Assistant T
Configure the feature via Hicom Assistant T as follows:
Step Action
1. Configure call charge factor
*9531994
2. 11-4 => Call detail record - Edit Charge Factor
3. Configure call charge factor ISDN
*9531994
4. 11-5 => Call detail record - ISDN Factor
5. Configure currency unit
*9531994
6. 11-6 => Call detail record - Currency Unit
Programming Feature Via Hicom Assistant E
Configure the feature via Hicom Assistant E as follows:
Step Action
Hicom 150 E Office Rel.1.0 Service Manual - 7.12 Features for Call Detail Recording
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_712.htm (3 of 21) [06/04/2000 13:08:17]