Depending on the composition of the wall, additional fixing accessories may be required
(for example wood screws for wooden walls).
Procedure
Step Action
1. Loosen and remove sunshade.
2. Loosen triangular head screws connecting outdoor casing to mounting plate and remove
outdoor casing. Open casing (four triangular head screws in cover).
3.
Drill two holes for plugs (8 mm ) into wall (spacing measurements shown in Figure 12-3).
The plug holes for the wall mounting plate should be at the upper right and lower left.
When selecting a site for mounting the BS, ensure that there is sufficient space for the
mounting plate.
4. Insert plugs.
5. Remove mast blocks from mounting plate.
6. Fix mounting plate to wall with two screws.
7. Hang outdoor casing on the two triangular head screws of the mounting plate. Tighten
triangular head screws.
8. If necessary:
Feed lead seal wire through lower right fastening hole of outdoor casing and lead seal wire
hole of mounting plate (see Figure 12-4). Seal wire.
9. Connect BS (see Section 12.3.3).
10. Using adhesive tape, fix BS onto heating board plate (see Figure 12-6). Then place BS and
heating board plate into the cavity provided in the outdoor casing. Ensure that it fits securely.
The heating board for regulating the temperature in the outdoor casing has not yet been
released for operation with Hicom cordless 150 E Version 1.0!
DO NOT connect the heating board! This could cause the system to malfunction due to
self-heating.
Step Action
11. Close outdoor casing cover using the four triangular head screws.
12. Mount sunshade (if required). To do this, clip panel into holes on the side of the mounting
plate (see Figure 12-6).
12.3.2.3 Outdoor wall mounting without mounting plate
When mounting on the wall WITHOUT the mounting plate, the sunshade CANNOT be
mounted.
Hicom 150 E Office Rel.1.0 Service Manual - 12 Cordless Multicell Integration CMI
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_12.htm (9 of 45) [06/04/2000 13:05:55]