3. Connect system to power supply A continuous numbering plan is generated (as was the case
when the system was first initialised).
Notes:
Changes to the extension numbers result in changes
to the individual, extension-specific data.
Only those ports provided for in accordance with the
maximum configuration are activated if the
maximum line configuration is exceeded (too many
trunk boards).
A mixture of subscriber line circuits and trunk lines
on one STMD8 can result in gaps in line numbering.
This is because all STMD8 ports are initially
activated as trunks and are only subsequently
reconfigured.
5.1.4 Carrying out the country initialisation
You should carry out the country adaptation on the system telephone with internal extension 100 (port
01). This process loads the country-specific data and ensures that the system meets the country's
conditions for approval.
No country adaptation is necessary for Germany after a reload since the system starts up with the
BRD code.
Input procedure
Table 5-5 Entering the country code
Step Input Description
1. *95 System administration code
2. xxxxxxxx 8-digit country code (Table 5-6)
The entry of the country code initiates system bootstrapping. Any data that has already been stored,
such as system speed-dialling destinations and classes of service, are deleted or reset to their default
values.
The system ensures that the correct default data is uploaded after the input of a country code
(exception: in the case of an official release of the system (software) for this country).
Country codes
Table 5-6 Country codes
Country Code Country Code
Argentina 99195953 Malaysia 76010255
Australia 99168546 Netherlands 49545821
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_5m.htm (5 of 7) [06/04/2000 13:06:35]