8.20 Configuring a second V24 interface
Introduction
The second V.24 interface is used for connecting Plus products.
Example
The second V.24 interface is to be configured for call detail recording central (CDRC) at a baud rate
of 2400 bd.
Programming with Hicom Assistant T
Step Entry Action Display
1. *95 31994 Start system administration System Administration
2. 22-13-1 Configure the V24 interface V.24 port 1: 9600 bd
3.
+
Scroll to V24 port 2 V.24 port 2: 9600 bd
4.
* 2400
Change the baud rate from 9600 bd to 2400 bd V.24 port 2: 2400 bd
5. F7 2 1 Port assignment for Charges/System V.24 port: -
6.
* 2
Charges/System V.24 port: 2
7. F8-F7 Exit system administration Set time, Set date
Programming with Hicom Assistant E
Step Action
1. System status -> Call charges -> Output format
The baud rate cannot be changed with this tool!