8.2 Call detail recording using a call charge
computer (GCM, Teledata)
Settings in the system
Programming with Hicom Assistant T
Step Code Action Display
1. *95 31994 Start system administration System Administration
2. 22-13-1 Set baud rate
(2400 bd or 9600 bd)
2400 or 9600 bd
3. 22-13-2-11 Select output port:
U
P0/E
or V.24
Port:
0 = none
1 = V.24 port
2 = U
P0/E
port
4. 22-13-2-12 Select interface:
1 or 2 for OfficePro
1 to 5 for OfficePoint/OfficeCom
(interface 2-5* must be installed)
V.24 Port
5. 11-3-1 Set call data record output to "Compressed" Output:
Compressed
6. 11-3-3 Set incoming calls to "No" Output: No
7. 11-7 Set call log to "No" Output: No
* = interface 2-5 set permanently to 2400 bd
Programming with Hicom Assistant E
Step Activity
1. Port settings for CDRC
System status -> Call charges -> Output format
The baud rate can only be set with Assistant T!