8.8 Configuring an ISDN system interface
Introduction
Enter the system extension number without prefix and without attendant code.
DID is not possible without a system extension number!
The system extension number must be entered for each route.
Example
Country: 49
Prefix: 02302
System extension number: 4711-0
Programming with Hicom Assistant T
Step Entry Action Display
1. *95 31994 Start system administration System Administration
2. 20-2 Select the route telephone number Route tel. number
3. 1 Select the local no. Rte 1: -
4.
* 4711
Enter the local number Rte 1: 4711
5. F2 Go to: National No. Rte 1: -
6.
* 2302
Enter the national number Rte 1: 2302
7. F2 Go to: International No. Rte 1:
8.
* 49
Enter the international number Rte 1: 49
9. F8 F7 Exit system administration Set time, Set date
Programming with Hicom Assistant E
Step Action
1. Options -> Lines / networking -> Routes
| Siemens | Home | First Page | Previous Page | Next Page | Search | Info | Help |
© Siemens AG, München, 1998
Hicom 150 E Office Rel.1.0 Service Manual, 2, 1998-06-26
Siemens Part No.: P31003-M1530-X403-2-7620
Conversion Date: 1998-09-18
Hicom 150 E Office Rel.1.0 Service Manual - 8.8 Configuring an ISDN system interface
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_88.htm [06/04/2000 13:12:32]

Table of Contents

Other manuals for Siemens Hicom 150 E Office

Related product manuals