Call Forwarding No Reply CFNR
Same as CFU but only if the call is not answered within a specified period of time (15 seconds).
Model-Specific Data
Subject OfficePro OfficeCom OfficePoint OfficeOne
Feature available in x x x x
HW requirements S
0
module -
SW requirements As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0
CO feature x x x x
Extension feature x x x x
Dependencies/Limitations
Subject Dependency/Limitation
CFW Not possible with an S
2M
port
CFW In the case of a telecommunications port, forwarding applies to the entire port; with an
MDC port, only the MSN assigned to the extension with programming authorisation is
forwarded. If an MSN has not been assigned to this terminal, forwarding cannot be
activated.
CFW Forwarding is always performed for the first basic port, i.e. the first S
0
port must also be
present in the system.
S
0
internal Only CFU is supported for internal extensions as otherwise conflicts with call
management may occur.
7.13.9 Call Deflection (CD)
Definition
If an extension has activated forward by network, Hicom 150 E Office attempts to forward this call to
the CO using this feature. In this case, when the call is received the CO is informed of the new call
destination and the extension number of the forwarding extension. If external forwarding using call
deflection is not possible, the call is forwarded via the PABX.
Model-Specific Data
Subject OfficePro OfficeCom OfficePoint OfficeOne
Feature available in x x x x
HW requirements S
0
module -
SW requirements As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0
CO feature x x x x
Extension feature - - - -
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_713.htm (7 of 16) [06/04/2000 13:11:53]