Table 5-9 CBFC - board status display
LED H9 (green) Function
Off No power
On Power on, reset switch pressed
Off Power on, Reset switch held down (for approx. 5s), reload
On System boot
Flashing Normal operating state
Integrated modem status display
Table 5-10 CBFC - status display for the integrated
modem
LED H10 (green) Function
Off No integrated modem is installed
On Integrated modem is ready
Flashing Data traffic via integrated modem
Refer to Section 13.3.1 and Section 13.3.2.2 for the LED signalling concept.
Modem access via B channel is also supported. The green LED does not provide a status
display for this type of modem.
5.2.3 Carrying out the country initialisation
You should carry out the country adaptation on the system telephone with the extension number 100
in the case of OfficeCom and 11 in the case of OfficePoint/OfficeOne (port 01). This process loads
the country-specific data and ensures that the system meets the country's conditions for approval.
No country adaptation is necessary for Germany after a reload since the system starts up with the
BRD code.
Input procedure
Table 5-11 Entering the country code
Step Entry Explanation
1. *95 System administration code
2. xxxxxxxx 8-digit country code (Table 5-12)
Note
The entry of the country code initiates system bootstrapping. Any data that has already been stored,
such as system speed dialling destinations and classes of service are deleted or reset to their default
values.