Performing Feature Check
Check the feature for error-free functioning as follows:
Step Action
1. Set up a call.
2. Initiate an enquiry call.
3. Call another extension.
4. Perform an unscreened transfer.
5. Do not answer the call at the transferred extension. After the timer expires, the call should
return in the form of a recall.
7.1.11 Detecting the Signalling Method of a/b Stations
Definition
After the system has booted all analog subscriber ports are set to tone dialling. If an analog subscriber
port has to be switched to pulse dialling, both Hicom Assistant T and Hicom Assistant E can be used
to do this. The system need not be reset after the signalling method has been changed. The new
signalling method is operational immediately.
Model-Specific Data
Subject OfficePro OfficeCom OfficePoint OfficeOne
Feature available in x x x x
HW requirements - - - -
SW requirements As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0
Dependencies/Limitations
Subject Dependency/Limitation
Signalling method If a DP signal is detected, the code receiver remains activated in order to avoid
circumvention of the toll restriction facility.
Configuration options
The feature can be configured using:
Hicom Assistant T / Hicom Assistant E
Programming Feature Via Hicom Assistant T
Configure the feature via Hicom Assistant T as follows:
Step Action
Hicom 150 E Office Rel.1.0 Service Manual - 7.1 Features for all traffic types