3. Double-click on parameter for relevant extension
4. Flags
Performing Feature Check
Check the feature for error-free functioning as follows:
Step Action
1. Place a call to an internal subscriber who is engaged in an internal or external call.
2. Dial the override code (*62).
3. Call override/intrusion is indicated to the parties by means of a warning tone at the beginning
of the call override.
7.1.14 Overload indication
Definition
An overload indication (attendant console) can be activated for a fixed extension (first subscriber port
in the system). Pressing the appropriate key displays the waiting calls (key LED). The following
signalling methods are available:
Flashing: call waiting and AC busy
Flickering: waiting call was not answered within 30 seconds; there are more calls than can be
processed by the attendant console
Off: no AC overload
Model-Specific Data
Subject OfficePro OfficeCom OfficePoint OfficeOne
Feature available in x x x x
HW requirements digital subscriber module -
SW requirements As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0
Dependencies/Limitations
Subject Dependency/Limitation
Overload indication For France only
Overload indication A LED that is already "flickering" is not reset to "flashing".
Configuration options
The feature can be configured using:
Hicom Assistant T / Hicom Assistant E
Hicom 150 E Office Rel.1.0 Service Manual - 7.1 Features for all traffic types