8.23 Programming a sensor as an alarm dialling
device
Introduction
If you close an external contact (sensor) a signal is applied to a defined destination.
This destination can be an internal station, an internal group or an external telephone number.
Example
A message from sensor 1 is to be signalled at extension 12.
Programming with Hicom Assistant T
Step Entry Action Display
1. *95 31994 Start system administration System Administration
2. 27-1 Call up the Destination Number menu for the sensor (a
sensor can be directly selected with #)
Select Sensor 1:-
3.
* 12
Define the destination number for the sensor Select Sensor 1: 12
4. F8-F7 Exit system administration Set time, Set date
Programming with Hicom Assistant E
Step Action
1. Options -> Trunk modules -> Sensors
| Siemens | Home | First Page | Previous Page | Next Page | Search | Info | Help |
© Siemens AG, München, 1998
Hicom 150 E Office Rel.1.0 Service Manual, 2, 1998-06-26
Siemens Part No.: P31003-M1530-X403-2-7620
Conversion Date: 1998-09-18
Hicom 150 E Office Rel.1.0 Service Manual - 8.23 Programming a sensor as an alarm dialling device