EasyManua.ls Logo

Siemens Hicom 150 E Office - Audible Tone Monitoring

Siemens Hicom 150 E Office
672 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Step Action
1. Configure en-bloc dialling
Options
2. Least cost routing
Performing Feature Check
Check the feature for error-free functioning as follows:
Step Action
1. Configure least cost routing with en-bloc dialling.
2. Dial an external number.
3. The trunk line is only seized when the timer expires and full dialling is transmitted.
7.6.7 Audible Tone Monitoring
Definition
Connection setup via analog lines is always linked to audible tone monitoring. The line is checked to
determine whether the audible tone is present. The dialling information is not transmitted to the
central office until this check has been performed.
The reason for this is that the time until the CO dial tone is received may differ depending on the
network operator and network status.
Audible tone monitoring is performed:
after line seizure.
after dialling of administrable digits (e.g. discriminating digit in the PABX, LCR).
when a second audible tone is monitored.
Model-Specific Data
Subject OfficePro OfficeCom OfficePoint OfficeOne
Feature available in x x x _
HW requirements Analog trunk board _
SW requirements As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0 _
Dependencies/Limitations
Subject Dependency/Limitation
Audible tone If audible tone monitoring is not possible or not desired, a "pause before dial" can be
configured.
Audible tone The monitoring of a second audible tone and the audible tone monitoring time can be
modified via Hicom Assistant E only.
Hicom 150 E Office Rel.1.0 Service Manual - 7.6 Features for outgoing external traffic
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_76.htm (9 of 21) [06/04/2000 13:10:45]