1. Configure call charges
System status
2. Call charges
3. Output format
Performing Feature Check
Check the feature for error-free functioning as follows:
Step Action
1. Conduct a chargeable call.
The charges for this call are displayed as per programming.
7.12.3 Call Duration Display on Terminal
Definition
A call duration display is provided for external calls (outgoing or incoming) when no call charge
information is available.
The starting point for call detail recording is set for analog lines by means of a timer (5 seconds after
end of dialling).
In the case of digital trunk lines, recording is started when the call is received (at "CONNECT").
Model-Specific Data
Subject OfficePro OfficeCom OfficePoint OfficeOne
Feature available in x x x x
HW requirements optiset E
terminal with
display
optiset E
terminal with
display
optiset E
terminal with
display
optiset E
terminal with
display
SW requirements As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0
Dependencies/Limitations
Subject Dependency/Limitation
S
0
/ CMI terminal In the S
0
and CMI terminals the call duration display is not supported by the
system.
Configuration options
This feature does not have to be explicitly configured.