HW requirements
(terminal)
optiset E terminal with display
SW requirements As of Rel. 1.0
General requirements Call charge information from the public network
Dependencies/Limitations
Subject Dependency/Limitation
Call charges Each call segment is assigned to the subscriber who accepted the segment.
Conference In the case of the conference feature, every external call is recorded separately as an
individual segment.
Pay phone A subscriber can only query call charges from call segments that were conducted from
the assigned "pay phone".
Configuration options
The feature can be configured using:
Hicom Assistant T / Hicom Assistant E
Programming Feature Via Hicom Assistant T
Configure the feature via Hicom Assistant T as follows:
Step Action
1. Configure call charge factor
*9531994
2. 11-4 => Call detail record - Edit Charge Factor
3. Configure call charge factor ISDN
*9531994
4. 11-5 => Call detail record - ISDN Factor
5. Configure currency unit
*9531994
6. 11-6 => Call detail record - Currency Unit
7. 11-8 => Call detail record - Pay phone
Programming Feature Via Hicom Assistant E
Configure the feature via Hicom Assistant E as follows:
Step Action
1.
Performing Feature Check
Hicom 150 E Office Rel.1.0 Service Manual - 7.12 Features for Call Detail Recording
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_712.htm (7 of 21) [06/04/2000 13:08:18]