Subject OfficePro OfficeCom OfficePoint OfficeOne
Feature available in x x x x
HW requirements - - - -
SW requirements As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0
No. of CFW operations that can be
activated simultaneously
150 50 20 20
Dependencies/Limitations
Subject Dependency/Limitation
Do not disturb CFW cannot be programmed on a terminal where do not disturb is
activated.
Call forwarding CFW chaining is not possible.
Ext. call forwarding Only one external CFW destination can be programmed under a key
on each terminal.
Ext. call forwarding When dialling external destinations, the destination number must be
prefixed by the CO route code.
Prime Line If Prime Line on (automatic line seizure) is active, you must press
the extension key before entering the extension number when
dialling internal destinations. In this case, the route code for external
destinations is not necessary.
Analog terminals When using a/b, S
0
and CMI terminals, you must wait for a
confirmation tone after entering external destinations.
Timed reminder, automatic
wake-up system
If a timed reminder is pending, it does not follow an activated CFW.
Configuration options
This feature does not have to be explicitly configured.
Performing Feature Check
Check the feature for error-free functioning as follows:
Step Action
1. Activate call forwarding (*1).
2. Select type (1 = all calls, 2 = external calls only, 3 = internal calls only).
3. Call the terminal.
4. The call should arrive at the destination extension according to the call forwarding type
activated (all calls, external calls only or internal calls only).
Hicom 150 E Office Rel.1.0 Service Manual - 7.2 Features for general incoming traffic
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_72.htm (11 of 48) [06/04/2000 13:09:57]