General requirements optiset E (standard, comfort, memory)
Dependencies/Limitations
Subject Dependency/Limitation
Configure key You must also enter the extension number when programming the key.
A/b port The a/b port must be configured as a fax machine or answering machine.
Info key The LED goes out when you press the key.
Configuration options
The feature can be configured using:
Hicom Assistant T / Hicom Assistant E
Programming Feature Via Hicom Assistant T
Configure the feature via Hicom Assistant T as follows:
Step Action
1. Configure key
*91 => Entry to key programming.
2. Press relevant key.
3. Assign `Fax/Answering Machine' to selected key.
4. Enter number of the fax/answering machine.
Programming Feature Via Hicom Assistant E
Configure the feature via Hicom Assistant E as follows:
Step Action
1. Configure key
Options
2. Set up station
3. Program keys
Performing Feature Check
Check the feature for error-free functioning as follows:
Step Action
1. Program key.
2. Place a call to the appropriate extension.
3. The programmed key will light up when the call is answered.
Hicom 150 E Office Rel.1.0 Service Manual - 7.2 Features for general incoming traffic