When analog trunk boards are used, the signalling method is automatically detected, provided that no
signalling method and no "dial pause" is configured.
Model-Specific Data
Subject OfficePro OfficeCom OfficePoint OfficeOne
Feature available in x x x _
HW requirements Analog trunk board _
SW requirements As of Rel. 1.0 As of Rel. 1.0 As of Rel. 1.0 _
Dependencies/Limitations
Subject Dependency/Limitation
Signalling method If the line is set to PABX, the DTMF method is activated.
Dial Pause If "Dial Pause" is configured, the DP method is activated.
Power reset (power failure) The signalling method that is detected is stored until the next power
reset (power failure).
Configuration options
The feature can be configured using:
Hicom Assistant T / Hicom Assistant E
Programming Feature Via Hicom Assistant T
Configure the feature via Hicom Assistant T as follows:
Step Action
1. Configure signalling method
*9531994
2. 21-1 => Analogue Parameters - Dial Type
Programming Feature Via Hicom Assistant E
Configure the feature via Hicom Assistant E as follows:
Step Action
1. Configure signalling method
Options
2. Lines / networking
3. Trunks
4. Flags
5. MSI flags
Performing Feature Check
Hicom 150 E Office Rel.1.0 Service Manual - 7.6 Features for outgoing external traffic
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_76.htm (12 of 21) [06/04/2000 13:10:46]