9.
* Tie
Route TIEL port 1, Route 2, Name -> Tie Rte 2: Tie
If applicable, assign route type PABX to TIEL port 1:
10.
F7 14 * 1
Program TIEL port 1 on PABX Rte 2: PABX
11. F8-F7 Exit system administration Set time, Set date
If it is necessary to adapt the signalling protocols, this must also be configured with Assistant E.
Programming with Hicom Assistant E
Step Action
1. Options -> Lines / networking
Adapt the signalling protocol:
2. Options -> Lines / networking -> Trunks -> double-click TIEL Param 1 -> MSI flags -> Set
Maintype
Note
The connection of the TIEL board via 2-wire or 4-wire cables is described in Section 3.3.8.
| Siemens | Home | First Page | Previous Page | Next Page | Search | Info | Help |
© Siemens AG, München, 1998
Hicom 150 E Office Rel.1.0 Service Manual, 2, 1998-06-26
Siemens Part No.: P31003-M1530-X403-2-7620
Conversion Date: 1998-09-18
Hicom 150 E Office Rel.1.0 Service Manual - 8.38 Analog tie traffic via TIEL boards