Type 3
S103
S102
1-2
4-6
1-3
S203
S202
1-2
4-6
1-3
S303
S302
1-2
4-6
1-3
S403
S402
1-2
4-6
1-3
2-wire speech
lines
S104 1-3
4-6
S204 1-3
4-6
S304 1-3
4-6
S404 1-3
4-6
4-wire speech
lines
(factory default)
S104 1-2
4-5
S204 1-2
4-5
S304 1-2
4-5
S404 1-2
4-5
Connection of the signal wires
The following maximum ranges (without a converter) must be taken into account:
- 4-wire speech: 8 km at 0.6 mm diameter
- 2-wire speech: 6 km at 0.6 mm diameter
E&M interface, type 1
Figure 3-28 E&M interface, type 1
E&M interface, type 1A
Hicom 150 E Office Rel.1.0 Service Manual - 3.3 Peripheral boards
http://cmweb01.mch.pn.siemens.de/e_doku/en/h150/h15/30/sh/2/15_32.htm (22 of 46) [06/04/2000 13:03:53]