Programmer’s Guide BCM5722
10/15/07
Broadcom Corporation
Document 5722-PG101-R BIST Registers Page 380
3 TxMbuf & Misc_BD
BIST Fail
Status indicating BIST test has failed. 1 RO
2 TxMbuf & Misc_BD
BIST Done
Status indicating BIST has completed when set (TXMBUF). 0 RO
1 RxMbuf BIST Fail Status indicating BIST test has failed. 1 RO
0 RxMbuf BIST Done Status indicating BIST has completed when set (RXMBUF). 0 RO
Table 411: BIST Status Register (Offset 0x7404) (Cont.)
Bit Field Description Init Access